Htr
AquaRest Spas Heater Circuit Failure

Display shows HTR ERR or HEATER ERR; spa will not heat though pumps may run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open heater element, Tripped high-limit that will not reset, Burned heater relay on control board, Loose heater wiring at control pack

How to Fix / Troubleshooting

Safety: Turn off power at the breaker and verify with a meter before touching heater terminals.

  • Step 1 – Inspect heater wiring: Open the control pack and check that the heater leads are securely fastened to the heater terminals and control board, with no signs of burning.
  • Step 2 – Check for leaks: Inspect the heater tube and unions for leaks that could damage electrical connections.
  • Step 3 – Test heater element: If qualified, use a multimeter to measure resistance across the heater terminals. An infinite reading indicates a failed element.
  • Step 4 – Replace heater: If the element is open or the tube is damaged, replace the heater assembly with an AquaRest-compatible unit, ensuring all O-rings and unions are properly sealed.

If the heater tests good but Htr persists, the control board heater relay may be defective and require professional replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heater Assembly
Check Price on Amazon

We may earn a commission from links on this page.