PF
AquaRest Spas
Power Failure Detected
Display shows PF or PFAIL after a power outage; spa may not resume normal operation until reset.
Advertisements
Possible Causes
Recent utility power interruption, Tripped GFCI breaker, Loose main power connections at control pack, Undersized or unstable power supply
How to Fix / Troubleshooting
Safety: Always turn off the breaker before tightening any electrical connections.
- Step 1 – Reset GFCI: Locate the spa's GFCI breaker or outlet and press the RESET button. Ensure the breaker handle is fully in the ON position.
- Step 2 – Power cycle spa: Turn the breaker off for 30 seconds, then back on. Allow the AquaRest control pack to complete its startup sequence.
- Step 3 – Inspect main connections: With power off, remove the control pack cover and verify that the incoming power wires are tight and free of corrosion or heat damage.
- Step 4 – Monitor for repeat PF: If PF recurs frequently without utility outages, have an electrician verify the supply voltage and wiring size to the spa.
Advertisements
Repair Difficulty
Easy
2/5