F7
Aquavia Spa
Low Line Voltage / Power Supply Fault
F7 error and spa may shut down or run only briefly before stopping.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Undersized supply cable, Loose terminal connections in spa junction box, Voltage drop due to long cable run, Utility supply issues
How to Fix / Troubleshooting
Safety first: Turn off power before opening any electrical enclosures. Only qualified persons should work on mains wiring.
- Check main connections: Inspect the incoming power terminals in the Aquavia Spa connection box. Tighten any loose screws and verify that the cable size matches the installation manual.
- Measure voltage (qualified only): With power on, a qualified electrician should measure voltage at the spa terminals while pumps and heater are running. Voltage significantly below the rated value can trigger F7.
- Correct wiring issues: If the cable is undersized or the run is excessively long, upgrade to the recommended conductor size. Repair any corroded or overheated terminals.
- Contact utility if needed: If supply voltage from the grid is unstable, contact your power provider.
Advertisements
Repair Difficulty
Professional Required
5/5