P2
Aquavia Spa Pump 2 Output Fault

P2 error and secondary massage pump will not operate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed Pump 2 motor, Loose Pump 2 connector, Damaged Pump 2 relay on control board, Incorrect pump configuration in control settings

How to Fix / Troubleshooting

Safety first: Isolate power at the breaker before working on Pump 2 or the control pack.

  • Check configuration: On some Aquavia Spa models, ensure that Pump 2 is enabled in the system configuration menu (refer to the user manual).
  • Inspect connectors: Confirm that the Pump 2 plug is fully seated in the correct socket on the control board and that the cable is undamaged.
  • Test pump: If possible, swap Pump 1 and Pump 2 connectors at the board briefly (with power off) to see if the fault follows the pump or stays with the output. Do not run pumps dry.
  • Replace faulty component: If the fault follows the pump, replace the Pump 2 assembly. If it stays with the board output, the Pump 2 relay or circuit is defective and the control board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pump 2 Assembly
Check Price on Amazon