P3
Aquavia Spa
Auxiliary Pump / Blower Output Fault
P3 error and third pump or blower does not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed blower or Pump 3 motor, Loose output connector, Overloaded auxiliary circuit, Faulty control board output
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before inspecting the blower or Pump 3.
- Inspect the auxiliary device: Locate the air blower or Pump 3. Check for water intrusion, damaged housing, or burnt smell.
- Check connections: Ensure the auxiliary device plug is firmly connected to the correct output on the Aquavia control board.
- Test device separately (qualified): A qualified technician can power the blower or pump from a test supply to confirm operation.
- Replace as needed: Replace the blower or Pump 3 if it fails to run when powered directly. If it runs but P3 persists, the control board output is likely faulty and requires replacement.