Aquavia Spa Reduced Jet Pressure / Hydraulic Imbalance

Jets are weak or uneven; some seats have very little water pressure.

Advertisements

Possible Causes

Dirty or clogged filter, Air lock in pump, Partially closed diverter valve, Debris in jet nozzles or pump wet end

How to Fix / Troubleshooting

Safety first: Turn off power before removing jets or opening unions.

  • Clean filter: Remove and rinse the Aquavia filter cartridge thoroughly. Replace if old or damaged.
  • Adjust diverter valves: Rotate any diverter valves on the spa rim to balance flow between seats.
  • Bleed pump: Loosen the union on the suction side of the pump to release trapped air, then retighten.
  • Clean jets: Remove individual jet inserts (where possible) and soak them in a mild descaling solution to remove calcium and debris. Rinse and reinstall.
  • Inspect pump wet end: If pressure remains low, check the pump impeller for debris or damage and replace the wet end if necessary.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Filter Cartridge
Check Price on Amazon

We may earn a commission from links on this page.