Aquavia Spa
Reduced Jet Pressure / Hydraulic Imbalance
Jets are weak or uneven; some seats have very little water pressure.
Advertisements
Possible Causes
Dirty or clogged filter, Air lock in pump, Partially closed diverter valve, Debris in jet nozzles or pump wet end
How to Fix / Troubleshooting
Safety first: Turn off power before removing jets or opening unions.
- Clean filter: Remove and rinse the Aquavia filter cartridge thoroughly. Replace if old or damaged.
- Adjust diverter valves: Rotate any diverter valves on the spa rim to balance flow between seats.
- Bleed pump: Loosen the union on the suction side of the pump to release trapped air, then retighten.
- Clean jets: Remove individual jet inserts (where possible) and soak them in a mild descaling solution to remove calcium and debris. Rinse and reinstall.
- Inspect pump wet end: If pressure remains low, check the pump impeller for debris or damage and replace the wet end if necessary.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Filter Cartridge
Check Price on Amazon
We may earn a commission from links on this page.