Aquavia Spa Seized Pump Motor or Failed Start Capacitor

Pump hums but does not start; may trip breaker after a few seconds.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn motor bearings, Debris jammed in impeller, Failed start/run capacitor, Low supply voltage to pump

How to Fix / Troubleshooting

Safety first: Turn off power and verify no voltage is present before touching the pump.

  • Check for obstructions: Remove pump unions and inspect the impeller for stones, plastic, or other debris. Clear any blockage.
  • Spin shaft manually: Try to rotate the motor shaft or rear cooling fan by hand. If it is stiff or seized, the motor likely needs replacement.
  • Inspect capacitor: Locate the capacitor on the motor housing. If it is bulged or leaking, replace it with an identical µF and voltage rating component.
  • Test operation: Reassemble, restore power, and briefly test. If the pump still only hums or trips the breaker, replace the complete pump assembly.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hydrotherapy Pump
Check Price on Amazon