Aquavia Spa Electrical Short or Ground Fault

Spa trips the breaker immediately or shortly after turning on.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Water intrusion in control pack, Shorted heater element to ground, Shorted pump motor, Incorrect wiring or neutral-ground fault

How to Fix / Troubleshooting

Safety first: This involves hazardous voltages. If you are not qualified, contact a licensed electrician or spa technician.

  • Visual inspection: With power off, open the equipment bay and inspect for obvious signs of water, burnt components, or melted wiring. Dry any moisture and correct leaks before reapplying power.
  • Isolate components: Disconnect heater, pumps, and blower one at a time from the control board. Restore power and see if the breaker still trips. The component that, when connected, causes tripping is likely faulty.
  • Test heater to ground: With wires removed, use a multimeter to check resistance between each heater terminal and ground. Any continuity indicates a ground fault and the heater must be replaced.
  • Repair wiring: Correct any miswiring or damaged insulation found in the junction box or control pack.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heater Assembly