DR
Arctic Spas Dry Fire Protection / Low Water in Heater

Display shows DR or DRY, heater is disabled; spa may attempt to start and then shut down with this code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient water level in spa, Air lock in heater manifold, Blocked filter or closed valves, Failed circulation pump preventing water through heater

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker. Running the heater without water can cause severe damage.

  • Check water level: Ensure the spa is filled to the proper level above all suction fittings and skimmers. Top up if low.
  • Clean filter: Remove and thoroughly rinse the filter cartridge. Try running the spa briefly without the filter to see if DR clears.
  • Open valves: Confirm all slice/knife valves around the pumps and heater are fully open.
  • Bleed air: Loosen unions at the pump and heater slightly to release trapped air until water seeps out, then retighten.
  • Check circulation pump: Restore power and verify that the Arctic Spas circulation pump is running and that you can see water movement in the spa.
  • Persistent DR: If DR returns and there is no visible flow, the circulation pump may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Arctic Spas circulation pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements