P2
Arctic Spas Pump 2 Circuit or Motor Fault

Display shows P2 ERROR or P2 FAIL, second jet pump does not run or trips breaker when activated.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed Pump 2 motor (Arctic Spas jet pump 2), Shorted pump windings, Loose or incorrect wiring on Pump 2 terminals, Undersized or failing GFCI breaker

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker and lock it out if possible.

  • Inspect Pump 2 wiring: Verify that the Pump 2 leads are correctly connected to the control pack terminals and that there are no signs of arcing or burning.
  • Check for moisture: Look for water leaks dripping onto the Pump 2 motor or wiring, which can cause shorts and breaker trips. Repair leaks before further testing.
  • Test motor windings: With the pump disconnected and power off, use a multimeter to measure resistance between motor leads and to ground. Very low resistance or continuity to ground indicates a shorted motor.
  • Breaker capacity: Confirm that the GFCI breaker size matches Arctic Spas specifications for your model. An undersized breaker may trip under normal load.
  • Replace pump if shorted: If windings are shorted or the motor is seized, replace the Arctic Spas Pump 2 assembly.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Arctic Spas jet pump 2