Arctic Spas No Heat Without Error Code

Spa will not heat, water stays cold even though pumps run and no error code is displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially failed heater element, Temperature set too low or in Economy/Sleep mode, Faulty temperature sensor reading too high, Weak circulation causing heater to cycle off

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before testing heater circuits.

  • Verify settings: Check that the spa is in Standard/Ready mode and that the set temperature is above current water temperature.
  • Check for heat call: When the spa calls for heat, the heater indicator on the topside should illuminate. If not, the control may not be commanding heat.
  • Test heater voltage: With a qualified person and power on, measure voltage at the heater terminals when there is a call for heat. Full line voltage should be present. If not, suspect the control board.
  • Measure heater resistance: With power off and heater disconnected, measure resistance across the heater element. Replace the Arctic Spas heater assembly if open or out of spec.
  • Check circulation: Ensure the circulation pump is running and that there is strong flow from the heater return.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Arctic Spas heater assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements