P2
Artesian Spas Pump 2 Overcurrent or Communication Fault

Display shows P2 error and Pump 2 will not run or trips breaker

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 2 motor, Shorted pump windings, Loose or burned wiring, Incorrect breaker size or wiring

How to Fix / Troubleshooting

Safety: Shut off power at the GFCI breaker before inspection.

  • Inspect Pump 2 wiring: Verify tight connections at both the pump and control pack. Look for discoloration or melted insulation.
  • Check pump rotation: With power OFF, attempt to spin the motor shaft by hand. If stiff or locked, the pump likely needs replacement.
  • Check breaker: Confirm the breaker size matches Artesian’s specifications for your model and that wiring is correctly sized.

If wiring and breaker are correct and the pump is seized or shorted, replace Pump 2 with an Artesian-compatible jet pump.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pump 2 (Jet Pump) for Artesian Spas
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements