Artesian Spas Ground Fault or Short Circuit

Spa trips the GFCI breaker immediately or within a few seconds of turning on

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heater element to ground, Water intrusion in pumps or control pack, Damaged wiring harness, Incorrectly wired GFCI breaker

How to Fix / Troubleshooting

Critical safety: Repeated breaker tripping indicates a potentially dangerous electrical fault. Do not bypass the GFCI or use a larger breaker.

  • Visual inspection: With power OFF, open the equipment bay and look for obvious water leaks, burned components, or melted wiring.
  • Isolate components (advanced): A technician can disconnect the heater, then pumps, then accessories one at a time from the control pack and re-energize to identify which component causes the trip.
  • Check GFCI wiring: Verify that line and load connections on the GFCI breaker are correct and that the neutral is wired per Artesian’s installation diagram.

Because of shock and fire risk, persistent GFCI tripping should be diagnosed and repaired by a qualified spa electrician or technician.

Advertisements

Repair Difficulty

Professional Required 5/5
Advertisements