Artesian Spas
Temperature Overshoot / Sensor Calibration Drift
Water temperature overshoots setpoint by several degrees before heater shuts off
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Aging temperature sensor, Poor sensor contact with heater manifold, Control board calibration drift
How to Fix / Troubleshooting
Safety: Turn off power at the GFCI breaker before handling sensors.
- Verify with thermometer: Compare displayed temperature to an accurate thermometer in the spa water.
- Inspect sensor mounting: Ensure the temperature sensor is fully seated in its well or threaded port on the heater manifold.
- Replace sensor: If readings are consistently off by more than 2–3°F, replace the thermistor with an Artesian-compatible part.
If overshoot persists with a new sensor, the control board may require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Heater Temperature Sensor (Thermistor) for Artesian Spas