FLO2
Artisan Spas Secondary Flow Circuit Error

Display shows FLO2 or FL2, often associated with a second pump or secondary flow circuit, heater may shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Flow restriction on second pump circuit, Faulty second pressure/flow switch, Air lock in secondary plumbing, Closed diverter or slice valve on secondary loop

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before opening unions or touching wiring.

  • Prime second pump: Run Pump 2 on low and high speed to purge air. If it will not prime, bleed the pump union.
  • Check valves and diverters: Ensure diverter valves feeding Pump 2’s jets are open and that slice valves on its suction and return lines are fully open.
  • Inspect secondary flow switch: Locate the second flow/pressure switch in the plumbing. Check wiring and replace if defective.

If FLO2 persists with good flow, the secondary flow switch or control board input may be faulty.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Secondary Flow Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements