E07
Avenli Ambient / Air Temperature Sensor Fault

E07 displayed and the spa will not heat; temperature reading may be erratic or stuck.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient temperature sensor, Sensor dislodged from mounting point, Damaged sensor wiring, Corroded connector at control box

How to Fix / Troubleshooting

Safety first: Disconnect power before handling any sensors or wiring.

  • Locate ambient sensor:
    • On many Avenli models, the ambient air temperature sensor is mounted near the control box or air intake.
    • Identify the small probe or thermistor and its cable.
  • Inspect cable and connector:
    • Check for cuts, abrasions, or crushed sections.
    • Unplug and replug the sensor connector at the control PCB to clean contacts.
  • Check sensor placement:
    • Ensure the sensor is not touching hot components like the heater tube.
    • Reposition it to its original clip or bracket so it measures true ambient air.
  • Replace sensor if damaged:
    • If the probe is broken or the cable insulation is cracked, replace with a compatible Avenli ambient temperature sensor.
  • If E07 persists: The sensor input on the main control PCB may be faulty, requiring control box replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor