E08
Avenli
Freeze Protection / Low Ambient Temperature Fault
E08 error and the spa stops heating; may occur when using the spa in very cold weather.
Advertisements
Possible Causes
Ambient temperature below operating range, Faulty ambient temperature sensor reading too low, Inadequate insulation around control box, Sensor not properly mounted
How to Fix / Troubleshooting
Safety first: Do not attempt to operate the spa outside the temperature range specified in the Avenli manual.
- Verify environment:
- Check the outdoor temperature; many Avenli spas are not designed for operation below approximately 4°C–5°C (39°F–41°F).
- If below this, allow the environment to warm or move the spa to a more sheltered location.
- Insulate control area:
- Ensure the control box compartment is closed and any factory insulation is intact.
- Avoid blocking ventilation openings.
- Check ambient sensor:
- Inspect the ambient temperature sensor for damage or dislodgement.
- Make sure it is not directly exposed to wind or ice.
- Reset and test: After environmental conditions improve, unplug the spa for 5 minutes, reconnect, and test. If E08 appears even in moderate temperatures, replace the ambient sensor.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor
Check Price on Amazon