E09
Avenli Air Blower Overheat / Overcurrent Fault

E09 displayed and the bubble (air) function will not start or stops abruptly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air intake, Water intrusion into air blower, Seized blower motor, Faulty blower thermal protector

How to Fix / Troubleshooting

Safety first: Unplug the spa before inspecting the blower or air lines.

  • Check air intake:
    • Locate the air blower intake grill on the control unit.
    • Remove any debris, leaves, or obstructions.
  • Inspect for water ingress:
    • Listen for sloshing sounds inside the blower housing.
    • If water is suspected inside the blower, do not operate it. The blower assembly must be removed, drained, and likely replaced.
  • Allow cooling:
    • If the blower has been used continuously for a long period, its thermal protector may have tripped.
    • Allow at least 30 minutes with the spa off to cool, then retry.
  • Test blower: After cooling and clearing the intake, reconnect power and briefly test the bubble function. If E09 returns immediately, the air blower motor or its thermal protector is likely defective.
  • Replace blower assembly: Install a compatible Avenli air blower assembly if the motor is seized or repeatedly trips overcurrent.