Beachcomber Air Lock or Pump Prime Loss

Pump runs but there is no water movement from jets (no flow).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Air trapped in pump housing after refill, Closed slice valves on suction or return, Broken pump impeller, Suction blockage at skimmer or footwell intake

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI before working on the pump.

  • Verify valves: Ensure all slice valves around the pump are fully open.
  • Bleed pump: Loosen the pump union on the discharge side slightly until air escapes and water begins to leak, then retighten.
  • Check suction: Inspect skimmer and suction fittings for obstructions.
  • Re-prime: Restore power and run the pump on high for 30–60 seconds to re-establish prime.

If the pump motor runs but never moves water, the impeller may be broken or the pump may be installed incorrectly and should be serviced.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Jet pump (2-speed) assembly
Check Price on Amazon

We may earn a commission from links on this page.