SN1
Bullfrog Spas High-Temperature Sensor (Sensor 1) Open or Disconnected

Control panel displays SN1 and spa will not heat; temperature reading is extremely low or shows dashes

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit in temp sensor harness, Failed M7 temperature sensor in heater tube, Corroded sensor plug at Bullfrog control pack, Damaged main control board sensor input

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker and verify with a non-contact voltage tester before opening any panels. Water and electricity are a lethal combination.

  • Power cycle the spa: Turn the GFCI breaker OFF for 2–3 minutes, then ON. If SN1 clears and does not return, it may have been a transient error.
  • Inspect the sensor cable: Remove the equipment compartment door. Locate the heater tube on the Bullfrog control pack (Balboa-style pack). Find the M7 sensor leads (usually two identical sensors threaded into the heater). Trace the cable from the sensor labeled as Sensor 1 to the control board. Look for cuts, rodent damage, or pinched insulation.
  • Check sensor connection: Gently unplug the Sensor 1 connector from the control board, inspect for corrosion or bent pins, then firmly reconnect. Do not pull on the wires; grasp the plug body.
  • Compare sensor resistance: With power still OFF, disconnect both M7 sensors and measure resistance with a multimeter. At typical spa water temperatures (80–100°F / 27–38°C), both sensors should read similar resistance (usually 10k–30k ohms depending on temperature). If Sensor 1 is open (infinite resistance) or drastically different from Sensor 2, it is defective.
  • Replace the sensor if needed: If Sensor 1 is faulty, drain water below the heater tube level, unscrew the sensor from the heater tube, and install a new Bullfrog-compatible M7 temperature sensor with the supplied O-ring. Hand-tighten only; do not overtighten. Reconnect the cable to the control board.
  • Restore power and test: Refill if needed, bleed air from the pump unions if you opened the plumbing, then turn the breaker ON and verify that SN1 is cleared and the spa heats normally.

If SN1 persists after replacing the sensor and verifying wiring, the sensor input on the main control board may be damaged; contact a Bullfrog Spas dealer or qualified spa technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

M7 Temperature Sensor (Sensor 1) for Bullfrog Control Pack
Check Price on Amazon

We may earn a commission from links on this page.