dY
Canadian Spa Company Persistent dry heater condition lockout

Display shows dY or DY after a dr error; spa may be locked out from heating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Heater overheated due to lack of flow, Severe air lock not cleared, Failed circulation pump, Severely restricted filter or suction

How to Fix / Troubleshooting

Safety: Leave power off at the GFCI until you have corrected the cause of the dry condition.

  • Resolve underlying dr cause: Follow the steps for the dr error: correct water level, open valves, bleed air, and ensure the circulation pump is working.
  • Inspect heater housing: Check the Canadian Spa Company heater tube for discoloration, warping, or leaks that may indicate dry-fire damage.
  • Replace damaged components: If the heater shows signs of overheating or leaking, replace the heater assembly before restoring power.
  • Clear lockout: Once the cause is fixed, leave power off for 5–10 minutes, then restore power. Some control systems require a longer power-off period to clear dY lockout.

If dY returns immediately, the control pack may have a permanent fault or the heater temperature sensor may be damaged and should be tested or replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heater Assembly for Canadian Spa Company Spa
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements