PF
Canadian Spa Company Power failure or low line voltage detected

Display shows PF or PFL and spa shuts down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Recent power outage, Loose connections at GFCI or spa pack, Undersized or overloaded circuit, Voltage drop due to long cable run

How to Fix / Troubleshooting

Safety: Only qualified persons should open electrical panels. Always turn off power at the main breaker before inspecting wiring.

  • Reset GFCI: Check the Canadian Spa Company GFCI plug or breaker and reset if tripped.
  • Inspect supply voltage: Have a qualified electrician measure voltage at the spa pack terminals while pumps and heater are running to ensure it is within specified range (e.g., 220–240V for 240V models).
  • Check connections: Verify that all lugs and terminals in the spa pack are tight and free of corrosion.
  • Reduce load: Avoid running multiple high-draw appliances on the same circuit as the spa.

Persistent PF errors require an electrician to correct supply issues or upgrade the circuit to Canadian Spa Company specifications.

Advertisements

Repair Difficulty

Hard 4/5
Advertisements