Canadian Spa Company Ozonator failure or blocked ozone line

Ozone generator not bubbling or ozone indicator not lit.

Advertisements

Possible Causes

Failed ozone generator, Clogged ozone check valve, Kinked ozone tubing, Ozone not enabled in control settings

How to Fix / Troubleshooting

Safety: Turn off power before working on the ozonator or tubing.

  • Check settings: Ensure ozone is enabled in the spa’s programming (if applicable).
  • Inspect tubing: Follow the ozone tubing from the ozonator to the injector. Straighten kinks and replace brittle tubing.
  • Check check valve: Replace the ozone check valve if it is clogged or allows water to backflow.
  • Replace ozonator: If the ozonator indicator never lights and no output is detected, replace it with a Canadian Spa Company-compatible ozone generator.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ozone Generator and Check Valve for Canadian Spa Company Spa
Check Price on Amazon