COL
Catalina Spas
Cold Water Protection / Freeze or Cool Condition
Display shows COL or COOL; spa stops heating and may run pumps to circulate cooler water.
Advertisements
Possible Causes
Water temperature sensor reading below safe threshold, Recently refilled spa with cold water, Freeze protection mode active, Sensor calibration drift
How to Fix / Troubleshooting
Safety: In freezing weather, protect the spa from ice damage. Do not drain the spa if temperatures are below freezing unless you fully winterize it.
- Step 1 – Confirm water temperature: Use a separate thermometer to verify actual water temperature. If the water is truly very cold, allow the spa to run; the system may be in a protective mode.
- Step 2 – Check for recent refill: If you just refilled with cold tap water, COL may appear until the spa warms up. Leave the cover closed and allow several hours for heating.
- Step 3 – Inspect sensor: If the displayed temperature is much lower than actual, inspect the temperature sensor and its wiring at the Catalina control pack. Loose or corroded connections can cause false low readings.
- Step 4 – Power reset: Turn off the breaker for 5 minutes, then restore. If COL persists with normal water temperature, the sensor may be out of calibration and should be replaced.
If you are in a freezing climate and the spa will not run pumps or heat, contact a technician immediately to prevent freeze damage.