dr
Catalina Spas Dry-Fire Protection / Low Water in Heater

Display shows dr or DRY; heater is disabled and spa may run pumps briefly then shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Air lock in heater manifold, Very low water level in spa, Blocked suction or closed slice valves, Failed or air-bound circulation pump

How to Fix / Troubleshooting

Safety: Turn off power before opening unions or valves. Running a heater without water can cause severe damage.

  • Step 1 – Check water level: Fill the spa so that the water level is above all jets and skimmer openings. Low water can draw air into the system.
  • Step 2 – Open all valves: In the equipment bay, verify that all slice valves on suction and return lines are fully open and locked.
  • Step 3 – Bleed air from pump and heater: With power off, slightly loosen the unions on the pump and heater until water seeps out, then retighten. This releases trapped air that can cause a dry condition.
  • Step 4 – Clean filters: Remove and rinse Catalina filter cartridges. Try running the spa briefly without filters to see if dr clears.
  • Step 5 – Reset and test: Turn power back on and run the pump on low speed. If dr returns quickly, the circulation pump may not be moving water and may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulation Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements