Possible Causes
Failed ozone generator, Clogged Mazzei injector or check valve, Cracked ozone tubing, Ozone output aged out (beyond service life)
How to Fix / Troubleshooting
Safety: Turn off power before handling ozone equipment. Avoid inhaling concentrated ozone.
- Step 1 – Visual check: With the circulation pump running, look for a steady stream of fine bubbles from the ozone injection point. No bubbles suggest a problem.
- Step 2 – Inspect tubing: Trace the ozone tubing from the generator to the injector. Replace any brittle, cracked, or kinked tubing.
- Step 3 – Check valve and injector: Replace the ozone check valve and clean or replace the injector if clogged with scale.
- Step 4 – Replace ozonator: Ozone generators typically last 2–3 years. If older and output is weak or absent, replace with a Catalina-compatible ozonator.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ozone Generator
Check Price on Amazon