COL
Clearwater Spas Cold Water Protection / Freeze or Low Temperature Condition

Display shows COL or COOL, heater does not run and spa may run pumps to warm water slightly.

Advertisements

Possible Causes

Water temperature below safe heating threshold, Temperature sensor reading very low, Spa just refilled with cold water, Sensor out of calibration

How to Fix / Troubleshooting

Safety first: Ensure the spa is filled and all plumbing is intact before running pumps in freezing conditions.

  • Verify actual water temperature: Use a separate thermometer to confirm the water temperature.
  • Allow warm-up: If the spa was just filled with cold water, allow the system to circulate; the code should clear as the water warms.
  • Check sensor placement: Make sure the temperature sensor is fully seated in its well or threaded port and not exposed to outside air.
  • Inspect sensor cable: Damage to the sensor cable can cause false low readings.

If COL persists with normal water temperature, the temperature sensor may need replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Temperature Sensor
Check Price on Amazon