P2
Coast Spas Pump 2 Overcurrent or Fault

Display shows P2 error; Pump 2 does not run or trips breaker when activated.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted Pump 2 motor, Debris jammed in Pump 2 impeller, Incorrect wiring of Pump 2 to Coast Spas control pack, Failed Pump 2 relay on control board

How to Fix / Troubleshooting

Safety first: Shut off power at the breaker and verify zero voltage before working on the pump.

  • Inspect wiring: Confirm Pump 2 is wired to the correct terminals and that no wires are loose or touching the cabinet.
  • Check for obstructions: Remove the wet end cover and inspect the impeller for stones, plastic, or other debris.
  • Spin test: Rotate the motor shaft by hand. If stiff or locked, replace the pump.
  • Board diagnosis: If a known-good pump still triggers P2, the control board relay may be damaged and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 2
Check Price on Amazon