Prr
Dream Maker Spas
Priming mode or pump prime error
Display shows Prr or PR and spa may not heat or run normally
Advertisements
Possible Causes
Spa just powered up and is in priming mode, Air lock in pump after refill, Pump not receiving power or seized
How to Fix / Troubleshooting
Safety first: Ensure the spa is completely filled before powering on. Running pumps dry can cause damage.
Priming steps:
- Allow priming cycle: After power-up, many Dream Maker Spas enter a priming mode (PR) for several minutes. Use the JETS button to cycle pumps on and off to purge air.
- Bleed air manually: If the pump only hums or no water moves, turn power OFF and loosen the pump union slightly until water seeps out, then retighten. Restore power and try again.
- Check slice valves: Ensure any gate/slice valves on either side of the pump are fully open.
- Verify pump operation: If the pump does not run at all, check for tripped GFCI or internal fuses. A seized pump may need replacement.
Advertisements
Repair Difficulty
Easy
2/5