SE
Dynasty Spas
Sensor or Software Error
Display shows SE or SEr, spa may not respond to keypad inputs or may behave erratically.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted control pack memory, Loose keypad or sensor connections, Electrical interference or power surge
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before unplugging any control components.
- Power cycle: Leave power off for at least 60 seconds, then restore. This can clear transient software errors.
- Check keypad cable: Inspect the topside control panel cable where it enters the control pack. Ensure it is fully seated and not damaged.
- Inspect sensors: Reseat all sensor connectors on the control board.
- Surge protection: If SE recurs after storms or power events, consider adding a surge protector and have the control pack evaluated by a technician.