P1
Everlast Spas Pump 1 Drive or Overload Fault

Display shows P1 error and Pump 1 will not start or runs erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 1 motor, Tripped thermal overload in Pump 1, Loose pump wiring at control pack, Defective pump relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before touching the pump or wiring.

  • Check for obstructions: Remove the Everlast spa filter and check for debris that could be blocking flow to Pump 1.
  • Spin shaft: With power OFF, try to rotate the Pump 1 motor shaft using a screwdriver at the rear fan opening. If seized, the pump will need replacement.
  • Inspect wiring: Verify that Pump 1 wires are tight at the control pack terminals and that there is no discoloration or melting.
  • Thermal reset: Allow the pump to cool for 30–60 minutes, then restore power and test. If P1 returns quickly, the pump motor or control relay may be failing.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 1
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements