P2
Everlast Spas
Pump 2 Drive or Overload Fault
Display shows P2 error and Pump 2 does not operate or trips breaker.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted Pump 2 motor windings, Debris jammed in Pump 2 wet end, Loose or burnt wiring, Defective Pump 2 relay on control board
How to Fix / Troubleshooting
Safety first: Shut off power and lock out the breaker before servicing Pump 2.
- Inspect wet end: Remove the Pump 2 union fittings and check the impeller area for stones, plastic, or other debris. Clear any obstruction.
- Check for leaks: Look for water leaking from the Pump 2 shaft seal, which can lead to motor failure.
- Test motor: A technician can perform resistance and insulation tests on the Pump 2 motor. Replace the Everlast Pump 2 assembly if windings are shorted.
- Control board check: If the motor tests good but P2 persists, the Pump 2 relay or triac on the control board may be defective and require board replacement.