PF
Everlast Spas Power Failure / Low Line Voltage Detected

Display shows PF or PFL and spa will not run; may occur after a power outage.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Recent power interruption, Loose connections at spa terminal block, Undersized or long wiring run causing voltage drop, Failing GFCI breaker

How to Fix / Troubleshooting

Safety first: Turn off the main spa breaker before opening the electrical compartment. Only qualified persons should work on high-voltage wiring.

  • Reset breaker: Turn the Everlast spa GFCI breaker fully OFF, then ON. Observe if PF clears.
  • Inspect connections: With power OFF, remove the control pack cover and verify that all line and neutral conductors are tight at the terminal block. Tighten loose screws to manufacturer torque specs.
  • Measure voltage: Using a multimeter, confirm that the spa is receiving the correct voltage (typically 240V for Everlast Spas) under load. If voltage is low, consult an electrician to correct wiring or breaker issues.
  • Replace faulty breaker: If the GFCI trips frequently or shows signs of overheating, have it replaced by a licensed electrician.
Advertisements

Repair Difficulty

Professional Required 5/5