SE
Everlast Spas Sensor Error / Sensor Out of Range

Display shows SE or SEr and controls may be unresponsive or behave erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or open temperature sensor, Moisture in sensor connector, Incorrect replacement sensor installed, Control board fault

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before handling electronics.

  • Dry connectors: Inspect the sensor connectors on the Everlast control pack for moisture. Dry thoroughly and apply dielectric grease if recommended.
  • Check sensor type: Ensure any replacement sensor is the correct type (e.g., 10k thermistor) specified for Everlast Spas.
  • Measure resistance: Test each sensor with a multimeter and compare to the temperature/resistance chart. Replace any sensor that is open, shorted, or far out of spec.
  • Board inspection: Look for burn marks or corrosion on the control board near the sensor inputs. If present, the control pack may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.