U1
Evolution Spas
Pump 1 Control or Relay Fault
Display shows U1 or U, pump 1 does not respond correctly to button presses.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck pump relay on control board, Loose pump 1 wiring at control pack, Failed pump 1 motor, Incorrect pump configuration
How to Fix / Troubleshooting
Safety: Turn off power at the GFCI breaker before touching any electrical connections.
- Check pump 1 wiring: Verify that the pump 1 wires are securely connected to the correct terminals on the control pack and that there are no signs of overheating.
- Test pump manually: If qualified, disconnect pump 1 and test it with a known-good power source of the correct voltage to confirm whether the motor runs.
- Inspect control board: Look for burned or discolored areas near the pump 1 relay.
If the pump runs when powered directly but not from the control pack, the control board relay is likely faulty and the board should be replaced.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Pump 1 (Two-Speed Jet Pump)
Check Price on Amazon