U1
Evolution Spas Pump 1 Control or Relay Fault

Display shows U1 or U, pump 1 does not respond correctly to button presses.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck pump relay on control board, Loose pump 1 wiring at control pack, Failed pump 1 motor, Incorrect pump configuration

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI breaker before touching any electrical connections.

  • Check pump 1 wiring: Verify that the pump 1 wires are securely connected to the correct terminals on the control pack and that there are no signs of overheating.
  • Test pump manually: If qualified, disconnect pump 1 and test it with a known-good power source of the correct voltage to confirm whether the motor runs.
  • Inspect control board: Look for burned or discolored areas near the pump 1 relay.

If the pump runs when powered directly but not from the control pack, the control board relay is likely faulty and the board should be replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pump 1 (Two-Speed Jet Pump)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements