Evolution Spas Air-Locked Jet Pump

Jet pump runs but no water comes out of the jets after refilling the spa.

Advertisements

Possible Causes

Air trapped in suction line, Pump not properly primed after refill, Closed suction valve, Loose pump union drawing air

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI breaker before loosening any unions.

  • Verify water level: Ensure water is above all suction fittings and skimmer.
  • Open valves: Confirm all suction and return valves to the pump are fully open.
  • Bleed pump: Loosen the union on the pump discharge side until air escapes and water begins to seep, then retighten.
  • Restart pump: Restore power and run the pump. Repeat bleeding if necessary until water flow is restored.

If the pump still will not prime, there may be a suction-side leak or internal pump issue requiring service.