Freeflow Spas Reduced Jet Pressure

Jets are weak or uneven; some jets barely flow even on high speed.

Advertisements

Possible Causes

Dirty filter, Air lock in jet pump, Partially closed slice valve, Debris in jet pump impeller

How to Fix / Troubleshooting

Safety first: Turn off power before removing filters or opening unions.

  • 1. Clean filter: Remove and thoroughly rinse the Freeflow filter cartridge. Test jet strength with the filter removed briefly.
  • 2. Open all valves: In the equipment bay, ensure all slice/ball valves on suction and return lines are fully open.
  • 3. Bleed pump: Loosen the union on the suction side of the jet pump until water flows, then retighten to remove trapped air.
  • 4. Check jets themselves: Many jets can be turned to adjust flow. Rotate each jet face counterclockwise to fully open.

If pressure remains low, the pump impeller may be clogged or the motor weakening, requiring pump service or replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Filter Cartridge
Check Price on Amazon

We may earn a commission from links on this page.