F7
Hanscraft Voltage Supply Error / Incorrect Line Voltage

F7 error displayed; spa may shut down heating and pumps intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring at spa terminal block, Low supply voltage, Loose main power connections, Internal power supply fault on control board

How to Fix / Troubleshooting

High-voltage hazard: Only perform electrical checks if you are qualified. Always turn off power at the breaker and lock it out before opening the electrical compartment.

  • Verify supply voltage: Have a qualified electrician measure the line voltage at the spa’s terminal block. Confirm it matches Hanscraft’s specified configuration (e.g., 230–240 V single-phase).
  • Check wiring configuration: Ensure that line, neutral, and ground wires are connected according to the Hanscraft wiring diagram inside the control box cover.
  • Tighten terminals: With power OFF, check that all terminal screws are snug. Loose connections can cause voltage drops and F7 errors.

If voltage and wiring are correct but F7 persists, the internal power supply on the control board may be defective and the board should be replaced by a technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Hanscraft Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements