Hydropool Topside Control Panel Degradation

Topside control panel display is dim, flickering, or unreadable, but spa still runs.

Advertisements

Possible Causes

Moisture intrusion into Hydropool topside, UV damage to display, Loose ribbon cable connection, Failing LED/LCD driver in panel

How to Fix / Troubleshooting

Safety: Turn off power before disconnecting the topside panel.

  • Inspect panel surface: Look for cracks or water under the lens. If moisture is present, the panel is likely compromised.
  • Check cable connection: Access the control pack and reseat the topside ribbon cable connector.
  • Drying attempt: If minor moisture is suspected, allow the panel to dry with the cover open and power off for 24 hours, then retest.
  • Replace panel: Persistent dim or unreadable displays require replacement of the Hydropool topside control with the correct part number.