SE
LA Spas General Sensor Error

Display shows SE or SENSOR, spa may shut down heating and pumps may continue to run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

One or more sensors out of range, Incorrect sensor type installed, Loose sensor connectors, Control board sensor circuit failure

How to Fix / Troubleshooting

Safety: Turn off power before opening the control box.

  • Identify sensors: LA Spas typically uses a spa temperature sensor and a high limit sensor on the heater tube. Confirm both are connected firmly to the control board.
  • Inspect for damage: Look for cuts, abrasions, or rodent damage on sensor cables.
  • Check resistance (advanced): Using a multimeter and sensor resistance chart, verify that each sensor's resistance matches the approximate water temperature. Replace any sensor that is far out of range.
  • Replace control board if needed: If known‑good sensors still trigger SE, the control board may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements