LA Spas Ozone Generator Failure

Ozone generator indicator is off and there is no ozone smell when the circulation pump runs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ozone generator module, Disconnected ozone tubing, Clogged ozone injector, No power output from control board ozone circuit

How to Fix / Troubleshooting

Safety: Turn off power before working on ozone equipment.

  • Check ozone indicator: Some LA Spas ozone units have an LED that should light when active. If off, verify power at the ozone output on the control board.
  • Inspect tubing: Ensure the ozone tubing is connected from the generator to the injector and not kinked or cracked.
  • Clean injector: Remove and soak the ozone injector in a descaling solution if clogged.
  • Replace generator: If power is present but the ozone unit does not operate, replace it with a compatible LA Spas ozone generator.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ozone Generator
Check Price on Amazon

We may earn a commission from links on this page.