E08
Lay-Z-Spa
PCB Communication / Internal Control Error
Lay-Z-Spa displays E08 and will not start heating; other functions may be limited.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Internal control board firmware fault, Corrupted memory or failed microcontroller, Moisture ingress on PCB, Loose internal connectors between display panel and main PCB
How to Fix / Troubleshooting
Safety first: Unplug the spa before handling the pump/heater unit. Do not open sealed electronics unless you are qualified.
- 1. Full reset: Disconnect power for at least 30 minutes to allow full discharge. Reconnect, reset the RCD, and attempt to start the spa.
- 2. Check for moisture: Inspect the outside of the control panel and pump housing for condensation, cracks, or water ingress. Dry the exterior thoroughly and ensure the unit is protected from rain.
- 3. Verify power supply: Plug the spa directly into a dedicated outlet (no extension leads) and confirm stable voltage. Fluctuating power can trigger control errors.
- If E08 persists: The main control PCB is likely defective. This is not user-repairable; the pump/heater unit or control board must be replaced by an authorized service center.