Lay-Z-Spa
Filter Housing Seal Failure
Lay-Z-Spa filter housing inside the spa keeps popping off or leaking around the threads.
Advertisements
Possible Causes
Cross-threaded filter housing, Worn or missing filter housing O-ring, Debris on sealing surfaces, Over-tightening causing distortion
How to Fix / Troubleshooting
Safety first: Turn off and unplug the spa before removing the filter housing.
- 1. Remove housing: Unscrew the filter housing and remove the cartridge.
- 2. Inspect O-ring: Check the O-ring on the housing for cracks, flattening, or missing sections. Replace if damaged.
- 3. Clean threads and seat: Wipe the threads and sealing surfaces on both the housing and liner port to remove grit or scale.
- 4. Reinstall carefully: Screw the housing on by hand, ensuring it is not cross-threaded. Tighten snugly but do not overtighten.
- 5. Test under pressure: Run the filter pump and check for leaks or movement.
- If it still pops off: The liner port threads may be damaged and require liner or port replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Filter Housing O-Ring
Check Price on Amazon
We may earn a commission from links on this page.