COL
Lifesmart Spas Cold Water Protection / Freeze or Low-Temperature Condition

Display shows COL or COOL, heater does not run, spa indicates water is too cold to heat normally.

Advertisements

Possible Causes

Water temperature below safe heating threshold, Faulty temperature sensor reading too low, Recently refilled spa with very cold water, Control pack in freeze-protection mode

How to Fix / Troubleshooting

Safety first: Ensure GFCI protection is working properly before leaving the spa powered in freezing conditions.

  • Verify actual water temperature: Use an external thermometer to compare with the displayed temperature. If the display is far off, the sensor may be faulty.
  • Allow water to warm gradually: If you just filled with very cold water, leave the cover on and allow the spa to run. The COL message should clear as the water warms.
  • Check circulation: Confirm that the circulation pump is running and that water is moving through the heater. Poor circulation can prevent proper temperature sensing.
  • Inspect temperature sensor: If the spa remains in COL mode despite warm water, inspect and, if necessary, replace the water temperature sensor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Temperature Sensor (Thermistor)
Check Price on Amazon