P2
Lifesmart Spas
Pump 2 Overload or Short
Display shows P2 ERR or P2, secondary jet pump does not run or trips breaker when activated.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted pump 2 motor windings, Water intrusion into pump motor, Loose or incorrect wiring, Overloaded circuit due to pump startup
How to Fix / Troubleshooting
Safety first: Shut off power at the GFCI breaker and do not repeatedly reset a tripping breaker.
- Visual inspection: Check Pump 2 for signs of water leakage into the motor or rust on the motor housing.
- Check wiring connections: Ensure Pump 2 wires are correctly landed on the control pack terminals and that insulation is intact.
- Isolate the pump: Disconnect Pump 2 from the control pack and restore power. If the breaker no longer trips, the pump is likely shorted and must be replaced.
- Replace Pump 2: Install a new OEM-compatible Lifesmart secondary jet pump, matching voltage and horsepower.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Pump 2 (Secondary Jet Pump)