Possible Causes
Failed ozone generator, Cracked or disconnected ozone tubing, Clogged ozone injector (Mazzei) fitting, Check valve installed backwards or stuck
How to Fix / Troubleshooting
Safety first: Turn off power before handling ozone tubing or components.
- Inspect tubing: Follow the small ozone tube from the ozonator to the injector fitting. Check for cracks, kinks, or disconnections.
- Check check-valve orientation: Ensure the ozone check valve is installed in the correct direction (arrow pointing toward the spa water).
- Clean injector: Remove the injector fitting from the plumbing and soak in a descaling solution to clear mineral buildup.
- Replace ozonator: If tubing and injector are fine but no ozone is produced, replace the ozonator with a Lifesmart-compatible unit.