P2
Master Spas Pump 2 Circuit or Overcurrent Fault

Display shows P2 error and Pump 2 does not operate correctly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 2 motor, Shorted pump wiring, Incorrect amperage draw, Failed pump relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before working on Pump 2.

  • Inspect Pump 2: Check for leaks around the wet end and ensure the motor spins freely by hand.
  • Verify wiring: Confirm Pump 2 is wired correctly to the control pack and that the wire gauge matches Master Spas specifications.
  • Test under load: With power restored, briefly activate Pump 2. If it trips the breaker or shows P2 immediately, the pump may be drawing excessive current and should be replaced.
  • Control board check: If a known-good pump still triggers P2, the control pack relay or circuitry may be damaged and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pump 2 (Jet Pump Assembly)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements