Prr
Master Spas Pressure Switch Error

Display shows Prr or PR and spa may not heat or may shut down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed pressure switch, Incorrect pressure switch adjustment, Low flow through heater, Loose pressure switch wiring

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before touching any electrical components.

  • Locate pressure switch: On some Master Spas models, a pressure switch is threaded into the heater manifold with two small wires going to the control pack.
  • Check flow first: Ensure filters are clean, water level is correct, and pumps are primed. Low flow can cause pressure switch errors.
  • Inspect wiring: Verify the pressure switch wires are firmly connected and not corroded or damaged.
  • Adjustment (if adjustable type): Some switches have an adjustment screw. Only make small 1/8-turn adjustments and test. Do not over-adjust to defeat safety.
  • Replace switch: If the switch does not open/close reliably with pump operation, replace it with a compatible Master Spas pressure switch.
  • Control pack issue: If a new switch and good flow still produce Prr, the control board may be faulty and should be evaluated by a spa technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.