SE
Master Spas Sensor Error / Sensor Out of Range

Display shows SE or SEr and controls may be unresponsive or erratic

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect sensor type installed, Loose sensor connector, Damaged sensor cable, Control pack firmware mismatch

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before unplugging sensors.

  • Identify sensors: Locate all temperature and high-limit sensors connected to the control pack.
  • Check connections: Unplug and firmly reseat each sensor connector. Inspect for corrosion or bent pins.
  • Verify correct parts: Ensure any recently replaced sensors are the correct Master Spas / Balboa-compatible 10k NTC sensors for your model.
  • Test resistance: Use a multimeter to confirm each sensor reads within expected range for the current water temperature.
  • Replace faulty sensor: If any sensor reads open, shorted, or far off spec, replace it.
  • Firmware/configuration: If SE persists with known-good sensors, the control pack may have a configuration or firmware issue that requires professional service or replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature Sensor Set
Check Price on Amazon