P1
Nordic Hot Tubs Pump 1 Circuit Failure

Display shows P1 ERR or P1 FAIL; pump 1 does not run or trips breaker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized pump 1 motor, Shorted pump 1 wiring, Failed pump relay on control board, Incorrect voltage configuration for pump 1

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before working on pumps or wiring.

  • Step 1 – Try to run pump 1: With power on, press the JETS 1 button and listen. A loud hum with no rotation suggests a seized motor; immediate breaker trip suggests a short.
  • Step 2 – Inspect wiring: With power off, check the pump 1 cable from the motor to the control pack for damage or loose connections.
  • Step 3 – Check for shaft rotation: Remove the rear motor cover and attempt to turn the shaft by hand with power off. If it is stuck, the pump may be seized.
  • Step 4 – Test motor windings: Use a multimeter to check resistance between motor leads and to ground. Very low resistance or continuity to ground indicates a shorted motor.
  • Step 5 – Replace pump or motor: If the motor is seized or shorted, replace the pump 1 assembly with a Nordic-specified pump.
  • Step 6 – Evaluate control board: If the pump tests good but never receives power, the pump 1 relay on the control board may be defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pump 1 Assembly
Check Price on Amazon